About the platform
This platform uses GIS-enabled, physics-informed urban building energy modeling (UBEM) to visualize building energy use, embodied carbon, operational carbon, and retrofit potential across Hong Kong. It supports building-level exploration and energy–carbon–economic comparisons of five retrofit measures: chiller, PV, envelope, window, and lighting.
How to use
- Select one or more of Hong Kong’s 18 districts in the right-hand Districts panel to display their buildings.
- Choose a visualization metric from Display metric on the left.
- Click a building to view its information. In Retrofit potential mode, explore the five measures in the IRR, payback period, and carbon reduction charts. Hover over a bar—or tap it on a touch screen—to see its value.
On smaller screens, the controls appear below the map. Expand Districts to select areas and scroll to view the charts.
Abbreviations
- EUI — Energy Use Intensity
- Annual energy use per unit of floor area. Here, EUI refers to electricity use, expressed in kWh/m²/year.
- IRR — Internal Rate of Return
- The discount rate at which the net present value of a retrofit investment’s cash flows equals zero, expressed as a percentage.
References
[1] Zhang, S., Chen, L., Xu, L., & Wang, Z. (2025). GeoBEM: A geospatial computing empowered framework for urban-scale building energy modeling. Sustainable Cities and Society, 121, 106203.
[2] Zhang, S., Chen, L., Huang, Q., Wang, X., & Wang, Z. (2026). An integrated energy–carbon–economic assessment of building decarbonization at city scale. Applied Energy, 424, 128406.